Command Reference Guide
192 ● flow-interval 3Com Router 5000 Family and Router 6000 Family
Command Reference
flow-interval
Purpose Use the flow-interval command to configure the interval for measuring the
average rate of the interfaces.
Use the undo flow-interval command to restore the default.
Syntax flow-interval seconds
undo flow-interval
Parameters seconds
Statistic interval in the range 1 to 1500 seconds.
If not specified, the default is 300 seconds.
Example Set the interval for measuring the average interface rate to 10 seconds.
[3Com ] flow-interval 10
Display information on Ethernet0/0/0.
[3Com ] display interface Ethernet 0/0/0
Ethernet0/0/0 current state :UP
Line protocol current state :UP
Description : Ethernet0/0/0 Interface
The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Internet Address is 202.82.28.28/28
Internet Address is 10.0.103.254/24 Sub
Internet Address is 10.0.102.254/24 Sub
IP Sending Frames’ Format is PKTFMT_ETHNT_2, Hardware address is
00e0-fc12-384f
Media type is twisted pair, loopback not set, promiscuous mode not set
100Mb/s, Full-duplex, link type is force link
Output flow-control is disabled, input flow-control is disabled
Output queue : (Urgent queue : Size/Length/Discards) 0/50/0
Output queue : (Protocol queue : Size/Length/Discards) 0/500/0
Output queue : (FIFO queuing : Size/Length/Discards) 0/75/0
Last 30 seconds input rate 138.36 bytes/sec, 1.63 packets/sec
Last 30 seconds output rate 5.59 bytes/sec, 0.13 packets/sec
Input: 492731 packets, 84128872 bytes, 492731 buffers
156266 broadcasts, 145584 multicasts, 0 pauses
79 errors, 78 runts, 0 giants
1 crc, 0 align errors, 0 overruns
0 dribbles, 0 drops, 0 no buffers
Output:230681 packets, 165591360 bytes, 230683 buffers
10916 broadcasts, 0 multicasts, 0 pauses
0 errors, 0 underruns, 0 collisions
0 deferred, 0 lost carriers
View This command can be used in the following views:
■ System view