Command Reference Guide
3Com Router 5000 Family and Router 6000 Family error-diffusion restraint config ● 165
Command Reference
error-diffusion restraint config
Purpose Use the error-diffusion restraint config command to set the three
parameters for error diffusion restraint function.
Use the undo error-diffusion restraint enable command to restore the
three parameters set for error diffusion restraint function to the default value.
Syntax error-diffusion restraint config detect-timer renew-timer threshold
undo error-diffusion restraint config
Parameters detect-timer
Detect timer (in seconds). Valid values are 30 to 600.
renew-timer
Renew time (in seconds). Valid values are 120 to 2400.
threshold
Error rate threshold (in seconds). Valid values are 5 to
100.
Default By default, the value of detect-timer is 30 seconds, renew-timer is 600 seconds and
threshold is 20%.
Example Configure detect timer for error diffusion restraint to 100 seconds and restore the
timer to 2400 seconds, error threshold to 15%.
[Router] error-diffusion restraint cofing 100 2400 15
View This command can be used in the following views:
■ System view
Description The value of renew-timer cannot be 4 times less than that of detect-timer. If the total
number of packets received in detect-timer time is less than 100, no error will be
counted.