Command Reference Guide
116 ● display controller t3 3Com Router 5000 Family and Router 6000 Family
Command Reference
display controller t3
Purpose Use the display controller t3 command to view state about a CT3
interface.
Syntax display controller t3 interface-number
Parameters interface-number
CT3 interface number.
Example Display the information related to the CT3 interface 3/0/0.
[3Com ] display controller t3 3/0/0
T3 3/0/0 current state :UP
Description : T3 3/0/0 Interface
Basic Configuration:
Work mode is CT3, cable length is 49 feet.
Frame-format is C-BIT Parity, line code is B3ZS.
Source clock is slave, loopback is not set.
Alarm state:
Receiver alarm state is none.
MDL state:
No message is sent now.
Message data elements:
EIC: line, LIC: line, FIC: line, UNIT: line
FI: line, PORT_NO: line, GEN_NO: line
Periodical detection is disabled.
FEAC state:
No code is sent now.
Periodical detection is enabled, no code received now.
BERT state:(stopped, not completed)
Test pattern: 2^7, Status: Not Sync, Sync Detected: 0
Time: 0 minute(s), Time past: 0 minute(s)
Bit errors (since test started): 0 bits
Bits received (since test started): 0 Mbits
Bit errors (since latest sync): 0 bits
Bits received (since latest sync): 0 Mbits
Historical Statistics:
Last clearing of counters: 14:39:02 UTC Sat 06/25/2005
Data in current interval (1 seconds elapsed):
0 Line Code Violations, 0 Far End Block Error
0 C-Bit Coding Violation, 0 P-bit Coding Violation
0 Framing Bit Err, 0 Severely Err Framing Secs
0 C-bit Err Secs, 0 C-bit Severely Err Secs
0 P-bit Err Secs, 0 P-bit Severely Err Secs
0 Unavailable Secs, 0 Line Err Secs
T3 1/0 CT1 1 is up
Frame-format ESF, clock slave, loopback not set
FDL Performance Report is disabled
Transmitter is sending none
Receiver alarm state is none
Line loop back deactivate code using inband signal last sent
BERT state:(stopped, not completed)
Test pattern: 2^11, Status: Not Sync, Sync Detected: 0