Working as DTE, the synchronous serial interface must accept the clock provided by
the remote DCE. As transmitting and receiving clocks of synchronization devices are
independent, the receiving clock of a DTE device can be either the transmitting or
receiving clock of the DCE device. So is the transmitting clock. Therefore, there are
four clock options are available for a DTE device.
The following table gives the four clock selection options
In the table, the clock ahead of = is the DTE clock and the one behind is the DCE
clock
Table 1 Clock options available for a synchronous serial interface working as DTE
Clockk selection option Description
DTEclk1 TxClk = TxClk, RxClk = RxClk
DTEclk2 TxClk = TxClk, RxClk = TxClk
DTEclk3 TxClk = RxClk, RxClk = TxClk
DTEclk4 TxClk = RxClk, RxClk = RxClk