clock (CE1/PRI Interface)
Purpose Use the clock command to set the clock mode on a CE1/PRI interface.
Use the undo clock command to restore the default clock mode on the interface.
Syntax clock { master | slave }
undo clock
Parameters master
Adopts the internal clock mode.
slave
Adopts the line clock mode.
Default By default, the CE1/PRI interface adopts the line clock mode (slave).
Example Set the clock mode of the CE1/PRI interface to internal clock (master) mode.
[3Com -E1 3/0/0] clock master
View This command can be used in the following views:
■ CE1/PRI Interface view
Description When a CE1/PRI interface is working as DCE, chose the internal clock for it, that is,
master clock mode. When it is working as DTE, chose the line clock, that is, slave