Command Reference Guide
3Com Router 5000 Family and Router 6000 Family speed ● 363
Command Reference
speed
Purpose Use the speed command to set the transmission rate on the user interface.
Use the undo speed command to restore the default.
Syntax speed speed-value
undo speed
Parameters speed-value
Transmission rate in bps. Available transmission rates
with asynchronous serial interfaces include the
following:
■ 300 bps
■ 600 bps
■ 1200 bps
■ 2400 bps
■ 4800 bps
■ 9600 bps (the default)
■ 19200 bps
■ 38400 bps
■ 57600 bps
■ 115200 bps
Example Set the transmission rate on the user interface to 19200 bps.
[3Com-ui-aux0] speed 19200
View This command can be used in the following views:
■ User Interface view
Description Only when the serial interface works in asynchronous flow mode can the
configuration be effective.