Command Reference Guide
168 ● sdlc max-pdu 3Com Router 5000 Family and Router 6000 Family
Command Reference
sdlc max-pdu
Purpose Use the sdlc max-pdu command to configure the maximum receivable frame
length of the SDLC.
Use the undo sdlc max-pdu command to restore the default value of the SDLC
maximum receivable frame length.
Syntax sdlc max-pdu n
undo sdlc max-pdu
Parameters n
The maximum receivable frame length of the SDLC.
Valid values are 1 to 17600 bytes.
Default By default, the maximum receivable frame length of the SDLC is of 265 bytes.
Example Configure the maximum receivable frame length of the SDLC as 512.
[3Com -Serial1/0/0] sdlc max-pdu 521
View This command can be used in the following views:
■ Synchronous Serial Interface view
Description The SDLC maximum frame length refers to the bytes of the largest packet that can be
received and sent, excluding the parity bit and the start/stop bit.
The maximum receivable frame length of some PU2.0 devices is of 265 bytes, and
that of IBM AS/400 is generally of 521 bytes. Usually we need to configure it the
same value as the connected SDLC device.