Command Reference Guide

96dlsw ethernet-backup timer 3Com Router 5000 Family and Router 6000 Family
Command Reference
dlsw ethernet-backup timer
Purpose Use the dlsw ethernet-backup timer command to configure the time for
which the master DLSw router waits before sending a positive or negative response to
the slave DLSw router upon receipt of a circuit establishing request.
Use the
undo dlsw ethernet-backup timer command to restore the default
wait time.
Syntax dlsw ethernet-backup timer value
undo dlsw ethernet-backup timer
Parameters value
Time for which the master router waits before sending
a positive or negative response to the slave router
upon receipt of a circuit establishing request. It is in the
range 100 to 5,000 ms and defaults to 500 ms.
Example Configure the master router in DLSw Ethernet redundancy to wait 1,500 ms before
responding to an IWANTIT frame.
[3Com ] interface ethernet 1/0/0
[3Com -Ethernet1/0/0] dlsw ethernet-backup enable 9999-9999-9999
priority 10
[3Com -Ethernet1/0/0] dlsw ethernet-backup timer 1500
View This command can be used in the following views:
Ethernet Interface view
Description With DLSw Ethernet redundancy, when a slave router wants to set up a circuit, it
sends an IWANTIT frame to the master router to request one. Upon receipt of the
IWANTIT frame, the master router needs to wait for a while before responding with a
UGOTIT or CKT_TKN frame to acknowledge or deny the setup request. The
dlsw
ethernet-backup timer
command is used to set the wait time.