Command Reference Guide

3Com Router 5000 Family and Router 6000 Family clns rdpacket interval 13
Command Reference
clns rdpacket interval
Purpose Use the clns rdpacket interval command to set the minimum interval to
generate RD packets.
Use the undo clns rdpacket interval command to revert to the default
minimum interval to generate RD packets.
Syntax clns rdpacket interval milliseconds
undo clns rdpacket interval
Parameters milliseconds
Minimum interval (in milliseconds) to generate RD
packets. Valid values are 0 to 4294967295.
If not specified, the default is 10.
Example Set the minimum interval to generate RD packets to 200 milliseconds.
<3Com > system-view
System View: return to User View with Ctrl+Z.
[3Com ] clns rdpacket interval 200
View This command can be used in the following views:
System view