Command Reference Guide
292 ● timeslot-set 3Com Router 5000 Family and Router 6000 Family
Command Reference
timeslot-set
Purpose Use the timeslot-set command to configure the timeslot set to perform R2
signaling and digital E&M signaling configurations.
Use the undo timeslot-set command to cancel the specified timeslot set.
Syntax timeslot-set ts-set-number timeslot-list timeslots-list signal {
e&m-delay | e&m-immediate | e&m-wink | r2 }
undo timeslot-set ts-set-number
Parameters ts-set-number
Specify the identification number of a certain Timeslot
set. Valid values are 0 to 30.
timeslots-list
Specify a timeslot range. The expression includes the
single digit, two digits separated by “,”, a pair of digits
separated by “-”, or the combination form (e.g., 1-14,
15, 17-31). The value range of digits is the integer
from 1 to 31.
signal
Specify the binding signaling mode of this Timeslot set,
which is generally used to configure the signaling
mode adopted by the central office. It includes the
following types of signaling:
■ e&m-delay Adopt the delay-start mode in the
digital E&M signaling.
■ e&m-immediate Adopt the immediate-start mode
in the digital E&M signaling.
■ e&m-wink Adopt the wink-start mode in the digital
E&M signaling.
■ r2 Specify that the signaling mode adopt ITU-T
Q.421 digital line signaling R2, which is the most
common configuration signaling.
Default By default, no TS set is configured, and if the digital E&M signaling is used, then
adopts e&m-immediate mode.
Example Create a timeslot set numbered 5, including 1 to 31 timeslots and using R2 signaling.
[Router-E1 1/0/0] timeslot-set 5 timeslot-list 1-31 signal r2
View This command can be used in the following views:
■ CE1/PRI Interface view