Command Reference Guide
3Com Router 5000 Family and Router 6000 Family default entity payload-size ● 71
Command Reference
default entity payload-size
Purpose Use the default entity payload-size command to configure the default
time length of voice packets with different coding formats.
Use the
undo default entity payload-size command to restore the
default.
Syntax default entity payload-size { g711 | g723 | g726r16 | g726r24 | g726r32
| g726r40 | g729 }
undo default entity payload-size { g711 | g723 | g726r16 | g726r24 |
g726r32 | g726r40 | g729 }
Parameters g711
Specifies the time length of voice packets with g711
coding. It can be 10 milliseconds, 20 milliseconds (the
default), or 30 milliseconds.
g723
Specifies the time length of voice packets with g723
coding, in the range 30 to 180 milliseconds. It defaults
to 30 milliseconds.
g726r16
Specifies the time length of voice packets with
g726r16 coding. It ranges from 10 to 110 milliseconds
and defaults to 30 milliseconds.
g726r24
Specifies the time length of voice packets with
g726r24 coding. It ranges from 10 to 70 milliseconds
and defaults to 30 milliseconds.
g726r32
Specifies the time length of voice packets with
g726r32 coding. It ranges from 10 to 50 milliseconds
and defaults to 30 milliseconds.
g726r40
Specifies the time length of voice packets with
g726r40 coding. It ranges from 10 to 40 milliseconds
and defaults to 30 milliseconds.
g729
Specifies the time length of voice packets with g729
coding, in the range10 to 180 milliseconds. It defaults
to 20 milliseconds.
Example Set the time length of voice packets with G.711 coding to 30 milliseconds.
[Router-voice-dial] default entity payload-size g711 30
View This command can be used in the following views:
■ Voice Dial Program view