Command Reference Guide

64default 3Com Router 5000 Family and Router 6000 Family
Command Reference
default
Purpose Use the default command to restore the default of all the R2 configurations and
reset the R2 call statistics to 0.
Syntax default
Parameters None
Example Restore the default of all the configurations on CAS 1/0/0:5.
[Router-E1 1/0/0] timeslot-set 5 timeslot-list 1-31 signal r2
[Router-cas 1/0/0:5] default
Table 1 Configuration items affected by the default command
Configuration item Default
The originating
exchange sends the
seizure
acknowledgement
signal.
ENABLE
The originating
exchange sends the
answer signal.
ENABLE
The originating
exchange answers at the
time of clear-back.
DISABLE
The originating
exchange answers with
the clear-back signal at
the time of
clear-forward.
DISABLE
Answer signal timeout
interval
60 seconds
Clear-forward signal
timeout interval
10 seconds
Seizure signal timeout
interval
1 second
Re-answer timeout
interval
1 second
Delay before sending
the release-guard signal
upon a timeout
10 second
Seizure
acknowledgement
signal timeout interval
40 seconds
The ABCD bit pattern
that represents an idle
receive line
1001
The ABCD bit pattern
that represents an idle
transmit line
1001