Command Reference Guide
3Com Router 5000 Family and Router 6000 Family cas ● 27
Command Reference
cas
Purpose Use the cas command to enter the R2 CAS view and digital E&M sigaling view.
Syntax cas ts-set-number
Parameters ts-set-number
The serial number of the Timeslot set predefined. Valid
values are 0 to 30.
Example Enter the R2 CAS view of No.5 Timeslot set.
[Router-E1 1/0/0] timeslot-set 5 timeslot-list 1-31 signal r2
[Router-E1 1/0/0] cas 5
View This command can be used in the following views:
■ CE1/PRI interface view
Description The command cas is used to enter the custom R2 CAS view. Under this mode various
parameters of the R2 signaling in the E1 interface can be configured as required. To
validate the custom R2 parameters, it is required to keep the parameter of
ts-set-number in the command cas consistent with the parameter set-number
in the command
timeslot-set.
Related Commands ■ timeslot-set
■ ani-offset
■ effect-time
■ reverse
■ select-mode
■ timer
■ trunk-direction
■ renew