Command Reference Guide

50standby timer routing-disable 3Com Router 5000 Family and Router 6000 Family
Command Reference
standby timer routing-disable
Purpose Use the standby timer routing-disable command to specify a delay for the
secondary link to be disconnected after the primary link goes up to avoid route
oscillation.
Use the undo standby timer routing-disable command to restore the
default delay, that is, 0.
Syntax standby timer routing-disable seconds
undo standby timer routing-disable
Parameters seconds
Delay for the dynamic routing standby module to
disconnect the secondary link. Valid values are 1 to
65535.
If no value is specified, the default value is 0.
Default By default, the secondary link is disconnected immediately.
Example On the interface BRI 0/0/0 disconnect the secondary link five seconds after the
primary link resumes.
[3Com -Bri0/0/0] standby timer routing-disable 5
On the interface BRI 0/0/0 disconnect the secondary link immediately after the
primary link resumes.
[3Com -Bri0/0/0] undo standby timer routing-disable
View This command can be used in the following views:
Dial Interface view
Description A dial interface refers to a physical dial interface such as PRI and BRI, or a logical dial
interface, that is, dialer interface.