flow interval
Purpose Use the flow-interval command to configure traffic statistic interval.
Use the undo flow-interval command to restore the default traffic statistic
interval. This command takes effect only on DCC packet-triggered dial-up.
Syntax flow-interval interval
undo flow-interval
Parameters interval
Traffic statistic interval (in seconds). Valid values are 1
to 1500.
If no value is specified, the default is 20 seconds.
Example Set the traffic statistic interval to 3 seconds.
[3Com ] flow-interval 3
View This command can be used in the following views:
■ System view
Description The command specifies intervals at which the system provides statistics about traffic
on the links in an MP bundle. It is applied to the situation where whether links are
brought up depends on traffic size. Changing the interval setting can affect the
interface traffic statistic interval that you can see when executing the
display
interfaces
command.
Related Commands ■ dialer threshold
■ display interface