Command Reference Guide
20 ● vrrp vrid timer advertise 3Com Router 5000 Family and Router 6000 Family
Command Reference
vrrp vrid timer advertise
Purpose Use the vrrp vrid timer advertise command to configure the Adver_Timer
of the specified standby group.
Use the undo vrrp vrid timer advertise command to restore the default.
Syntax vrrp vrid virtual-router-ID timer advertise adver-interval
undo vrrp vrid virtual-router-ID timer advertise
Parameters virtual-router-ID
VRRP standby group number. Valid values are 1 to 255.
adver-interval
Interval at which the master in the specified standby
group sends VRRP packets. Valid values are 1 to 255
seconds.
If not specified, the default is 1 second.
Example Set the master in standby group 1 to send VRRP packets at intervals of five seconds.
[3Com -Ethernet0/2/0] vrrp vrid 1 timer advertise 5
View This command can be used in the following views:
■ Ethernet Interface view
■ Bridge Template view
Description The Adver_Timer controls the interval at which the master sends VRRP packets.