Command Reference Guide
14 ● standby timer flow-check 3Com Router 5000 Family and Router 6000 Family
Command Reference
standby timer flow-check
Purpose Use the standby timer flow-check command to configure the interval for
checking the traffic size on the main interface.
Use the undo standby timer flow-check command to restore the default or
30 seconds.
Syntax standby timer flow-check interval-time
undo standby timer flow-check
Parameters interval-time
Flow checking interval, in the range 30 to 600
seconds.
If not specified, the default is 30 seconds.
Example Set Serial 1/0/0 to the standby interface of Serial 0/0/0, and configure the backup
bandwidth of the main interface on Serial 0/0/0.
[3Com ] interface serial 0/0/0
[3Com -Serial0/0/0] standby interface serial10/0/0 50
[3Com -Serial0/0/0] standby bandwidth 10000
[3Com -Serial0/0/0] standby threshold 80 50
[3Com -Serial0/0/0] standby timer flow-check 60
View This command can be used in the following views:
■ Interface view
Description When the main interface participates in backup load sharing, the backup center
automatically checks the traffic size on the main interface at intervals configured
using this command.
Before you can use this command, you must use the standby interface
command to specify physical interfaces or logical channels to back up the interface.