Command Reference Guide
208 ● info-center timestamp 3Com Router 5000 Family and Router 6000 Family
Command Reference
info-center timestamp
Purpose Use the info-center timestamp command to set a time stamp format for the
system information output to the information channels except for the log host.
Use the undo info-center timestamp command to cancel the current
configuration.
Syntax info-center timestamp { trap | debugging | log } { boot | date | none }
undo info-center timestamp { trap | debugging | log }
Parameters trap
Trap information
debugging
Debugging information.
log
Log information.
boot
Time elapses after the system boots. It is in the format
of xxxxxx.yyyyyy, where xxxxxx is the high 32 bits and
yyyyyy the low 32 bits of the passed milliseconds.
date
Current system date and time, in the format of
mm/dd/yyyy-hh:mm:ss.
none
No time stamp.
Default By default, the boot time stamp is used for debugging information while the date
time stamp is used for other types of information.
Example Set the time stamp format to boot for traps.
[3Com] info-center timestamp trap boot
View This command can be used in the following views:
■ System view