Command Reference Guide

3Com Router 5000 Family and Router 6000 Family data-flow-format 41
Command Reference
data-flow-format
Purpose Use the data-flow-format command to configure the unit of data flows sent to
the TACACS server.
Use the undo data-flow-format command to restore the default.
Syntax data-flow-format data [ byte | giga-byte | kilo-byte | mega-byte ]
data-flow-format packet [ giga-packet | kilo-packet | mega-packet |
one-packet ]
undo data-flow-format [ data | packet ]
Parameters data
Sets data unit.
byte
Sets ’byte’ as the unit of data flow.
giga-byte
Sets ’giga-byte’ as the unit of data flow.
kilo-byte
Sets ’kilo-byte’ as the unit of data flow.
mega-byte
Sets ’mega-byte’ as the unit of data flow.
packet
Sets data packet unit.
giga-packet
Sets ’giga-packet’ as the unit of packet flow.
kilo-packet
Sets ’kilo-packet’ as the unit of packet flow.
mega-packet
Sets ’mega-packet’ as the unit of packet flow.
one-packet
Sets ’one-packet’ as the unit of packet flow.
Default By default, the data unit is byte and the data packet unit is one-packet.
Example Set the unit of data flow destined for the HWTACACS server "3Com" to be kilo-byte
and the data packet unit be kilo-packet.
[3Com-hwtacacs-3Com] data-flow-format data kilo-byte packet kilo-packet
View This command can be used in the following views:
HWTACACS view
Related Command display hwatacs