Command Reference Guide

194isis timer lsp 3Com Router 5000 Family and Router 6000 Family
Command Reference
isis timer lsp
Purpose Use the isis timer lsp command to configure minimum IS-IS LSP interval on
the interface.
Use the undo isis timer lsp command to restore the default setting.
Syntax isis timer lsp time
undo isis timer lsp
Parameters time
Specifies the LSP interval (in milliseconds). Valid values
are 1 to 1000.
If no value is specified, the default value is 33
milliseconds.
Example Set the LSP interval on Interface serial1/0/0 to 500 milliseconds.
[3Com ] interface Interface serial1/0/0
[3Com -Serial1/0/0] isis timer lsp 500
View This command can be used in the following views:
Interface view
Related Command isis timer retransmit