Command Reference Guide

3Com Router 5000 Family and Router 6000 Family tcp timer syn-timeout 263
Command Reference
tcp timer syn-timeout
Purpose Use the tcp timer syn-timeout command to configure the TCP synwait timer.
Use the undo tcp timer syn-timeout command to restore the default value of
the timer.
Syntax tcp timer syn-timeout time-value
undo tcp timer syn-timeout
Parameters time-value
TCP synwait timer value (in seconds). Valid values are 2
to 600.
If no value is specified, the default TCP synwait timer
value is 75 seconds.
Example Configure the TCP synwait timer value as 55 seconds.
[3Com] tcp timer syn-timeout 55
View This command can be used in the following views:
System view
Description When a syn packet is sent, TCP enables the synwait timer. If the response packet is
not received before synwait timeout, the TCP connection will be disabled.
The configuration of this parameter needs to be implemented under the guidance of
the technical support engineers.
Related Commands tcp timer fin-timeout
tcp window