Command Reference Guide
3Com Router 5000 Family and Router 6000 Family x25 window-size ● 361
Command Reference
x25 window-size
Purpose Use the x25 window-size command to set the sizes of input and output
windows on the interface X.25.
Use the undo x25 window-size command to restore their default values.
Syntax x25 window-size input-window-size output-window-size
undo x25 window-size
Parameters input-window-size
Size of input window. When X.25 window modulus is
8, valid values are 1 to 7. When X.25 window modulus
is 128, valid values are 1 to 127.
If no value is specified, the default value is 2.
output-window-size
Size of output window. When X.25 window modulus
is 8, valid values are 1 to 7. When X.25 window
modulus is 128, valid values are 1 to 127.
If no value is specified, the default value is 2.
Example Set the receiving and sending window sizes on the X.25 interface Serial0/0/0 to 5.
[3Com-Serial0/0/0] x25 window-size 5 5
View This command can be used in the following views:
■ Interface view
Description This parameter in-packets determines the maximum number of correctly received
packets before X.25 sends the acknowledgement information. As long as the
bandwidth allows, the greater the window size, the higher the transmission efficiency.
Out-packets determines the maximum number of data packets sent by X.25
before it receives the correct acknowledgment information. As long as the bandwidth
allows, the greater the window size, the higher the transmission efficiency.
Please consult users’ ISP about the sending and receiving window sizes. Unless
supported by the network, do not set these two parameters to different values.
Related Commands ■ display interface
■ x25 map
■ x25 pvc
■ x25 switch pvc
■ x25 xot pvc