Command Reference Guide

3Com Router 5000 Family and Router 6000 Family x25 timer hold 353
Command Reference
x25 timer hold
Purpose Use the x25 timer hold command to set the delay to send calls to a destination
with failed calls.
Use the undo x25 timer hold command to restore its default value.
Syntax x25 timer hold minutes
undo x25 timer hold
Parameters minutes
Value of delay time (in minutes). Valid values are 0 to
1000. If the previous call failed at one destination, the
X.25 would not send calls to such a destination again
within the time set by this command.
If no value is specified, the default delay time is 0.
Example Set the parameter of the X.25 interface Serial0/0/0 to 5 minutes.
[3Com-Serial0/0/0] x25 timer hold 5
View This command can be used in the following views:
Interface view
Description Frequently sending call requests to a wrong destination (which does not exist or is
faulty) will deteriorate the operating efficiency of the 3Com
series router. The use of
this function can avoid this problem to a certain extent. If this parameter is set to 0, it
is equal to disabling the function. In addition, this function is only effective to the calls
originated from the local. That is to say, this parameter is meaningless when the X.25
operates in the switching mode.
Related Command display interface