Command Reference Guide

3Com Router 5000 Family and Router 6000 Family timer hold 313
Command Reference
timer hold
Purpose Use the timer hold command to set the timer to send keepalive packet.
Use the undo timer hold command to restore the default value.
Syntax timer hold seconds
undo timer hold
Parameters seconds
Time interval for the interface to send keepalive packet
(in seconds). Valid values are 0 to 32767.
If no value is specified, the default is 10.
Example Set the PPP timer hold to 20 seconds.
[3Com-Serial1/0/0] timer hold 20
View This command can be used in the following views:
Serial Interface view
Description For the very slow data links, the seconds parameter must not be set too small.
Because the long datagram can only be transferred totally after a long time, the
transfer of keepalive datagram is delayed. The data link would be regarded to be
broken if the interface has not received the keepalive packet from the other end for
many keepalive periods. When the keepalive time is set to a very long time, the link is
considered broken by the other end, and then is closed.
At the two ends of a PPP link, the same keepalive interval is recommended.
Related Command display interface