Command Reference Guide

312timer hold 3Com Router 5000 Family and Router 6000 Family
Command Reference
timer hold
Purpose Use the timer hold command to configure the polling timer at the DTE side.
Use the undo timer hold command to restore its default value.
Syntax timer hold seconds
undo timer hold
Parameters seconds
Value of polling timer (in seconds). Valid values are 0 to
32767. A value of 0 indicates that the LMI protocol is
disabled.
If no value is specified, the default is 10 seconds.
Example Configure that Frame Relay interface serial1/0/0 to work in DTE mode, and set the
value of polling timer to 15 seconds.
[3Com-Serial1/0/0] link-protocol fr
[3Com-Serial1/0/0] fr interface-type dte
[3Com-Serial1/0/0] timer hold 15
View This command can be used in the following views:
Interface view
Description The parameter defines the interval of Status-Enquiry packet sent by DTE.
Related Commands fr interface-type
fr lmi t392dce