Command Reference Guide
264 ● ppp mp max-bind 3Com Router 5000 Family and Router 6000 Family
Command Reference
ppp mp max-bind
Purpose Use the ppp mp max-bind command to configure maximum number of bound
links of MP.
Use the undo ppp mp max-bind command to restore the default configuration.
Syntax ppp mp max-bind max-bind-num
undo ppp mp max-bind
Parameters max-bind-num
Indicates maximum number of links that can be
bound. Valid values are 1 to 128.
Default By default, its value is 16.
Example Set the maximum number of bound links to 12.
[3Com-Virtual-Template10] ppp mp max-bind 12
View This command can be used in the following views:
■ Virtual Template Interface view
■ Dialer Interface view
Description Normally, it is not necessary to configure the parameter, which should be performed
under the guidance of technical engineers when necessary. Such a configuration may
have impact on the performance of PPP. If it is necessary to bind more than 16 PPP
channels, the parameter
max-bind-num can be changed.
If MP fails to delete links, it is possible that the maximum binding number is smaller
than the actually configured one. Make sure that the maximum binding number
should be larger than the actual one.
After you change the maximum number of links in an MP bundle on a
virtual-template or dialer interface, you must
shutdown and undo shutdown all
the physical interfaces to validate the modification.
Related Command ppp mp