Quick Specs

QuickSpecs
HP EliteDesk 705 G4 Business Desktops PCs
Standard Features and Configurable Components (availability may vary by country)
Not all configuration components are available in all regions/countries.
c06040429 DA16287 Worldwide Version 20 October 11, 2018
Page 77
DM
SFF
MT
80 PLUS Platinum
180W active PFC
90/92/89% efficient at
20/50/100% load (115V)
91/93/90% efficient at
20/50/100% load (230V
250W active PFC / 80 PLUS Platinum
400W active PFC / 80 PLUS Platinum
90/92/89% efficient at 20/50/100%
load (115V)
91/93/90% efficient at 20/50/100%
load (230V)
Operating Voltage Range
90Vac~264Vac
90Vac~264Vac
90Vac~264Vac
Rated Voltage Range
100Vac~240Vac
100Vac~240Vac
100Vac~240Vac
Rated Line Frequency
50HZ~60HZ
50HZ~60HZ
50HZ~60HZ
Operating Line
Frequency
47HZ~63HZ
47HZ~63HZ
47HZ~63HZ
Rated Input Current
65W1.6A
90W1.2A
150WW2.2A
250W3A
400W5.2A
250W3A
400W5.2A
Rated Input Current with
Energy Efficient* Power
Supply
65W1.6A
90W1.2A
150WW2.2A
250W3A
400W5.2A
250W3A
400W5.2A
DC Output
+19.5V
+12V
+12V
Current Leakage (NFPA
99: 2102)
Less than 500 microamps of
leakage current at 120 Vac with
the ground wire disconnected,
as required for Non-patient
Electrical Appliances and
Equipment used in a patient
care facility or that contact
patients in normal use. Per
section 10.3.5.1.
Less than 100 microamps of
leakage current at 120 Vac with
the ground wire intact with
normal polarity, as required for
Non-patient Electrical
Appliances and Equipment used
in a patient care facility or that
contact patients in normal use.
Per section 10.3.5.1.
Less than 500 microamps of
leakage current at 120 Vac with
the ground wire disconnected,
as required for Non-patient
Electrical Appliances and
Equipment used in a patient
care facility or that contact
patients in normal use. Per
section 10.3.5.1.
Less than 100 microamps of
leakage current at 120 Vac with
the ground wire intact with
normal polarity, as required for
Non-patient Electrical
Appliances and Equipment used
in a patient care facility or that
contact patients in normal use.
Per section 10.3.5.1.
Less than 500 microamps of leakage
current at 120 Vac with the ground
wire disconnected, as required for
Non-patient Electrical Appliances
and Equipment used in a patient care
facility or that contact patients in
normal use. Per section 10.3.5.1.
Less than 100 microamps of leakage
current at 120 Vac with the ground
wire intact with normal polarity, as
required for Non-patient Electrical
Appliances and Equipment used in a
patient care facility or that contact
patients in normal use. Per section
10.3.5.1.
Power Supply Fan
N/A
50mm variable speed
70mm variable speed
Power cord length
6.0 ft. (1.83 m)
6.0 ft. (1.83 m)
6.0 ft. (1.83 m)
External Power Adapter
External power supply
65W EPS, 89% average
efficiency at 115V & 230Vac
90W EPS, 89% average
efficiency at 115V & 230Vac
150W EPS, 89% average
efficiency at 115V & 230Vac
Internal power supply
Internal power supply
Dimensions
65W : 113.5mm x 55mm x
30mm
200mm x 85mm x 53mm
165mm x 95mm x 73mm