Quick Specs

QuickSpecs
HP ProDesk 600 G4 Business Desktops PCs
Standard Features and Configurable Components (availability may vary by country)
Not all configuration components are available in all regions/countries.
c06043924 DA16289 Worldwide Version 25 May 30, 2019
Page 89
DM
SFF
MT
AiO
Current Leakage (NFPA
99: 2102)
Less than 500
microamps of leakage
current at 264 Vac with
the ground wire
disconnected, as
required for Non-patient
Electrical Appliances and
Equipment used in a
patient care facility or
that contact patients in
normal use. Per section
10.3.5.1.
Less than 100
microamps of leakage
current at 264 Vac with
the ground wire intact
with normal polarity, as
required for Non-patient
Electrical Appliances and
Equipment used in a
patient care facility or
that contact patients in
normal use. Per section
10.3.5.1.
Less than 500
microamps of leakage
current at 264 Vac with
the ground wire
disconnected, as
required for Non-
patient Electrical
Appliances and
Equipment used in a
patient care facility or
that contact patients in
normal use. Per section
10.3.5.1.
Less than 100
microamps of leakage
current at 264 Vac with
the ground wire intact
with normal polarity, as
required for Non-
patient Electrical
Appliances and
Equipment used in a
patient care facility or
that contact patients in
normal use. Per section
10.3.5.1.
Less than 500
microamps of leakage
current at 264 Vac with
the ground wire
disconnected, as
required for Non-
patient Electrical
Appliances and
Equipment used in a
patient care facility or
that contact patients in
normal use. Per section
10.3.5.1.
Less than 100
microamps of leakage
current at 264 Vac with
the ground wire intact
with normal polarity, as
required for Non-
patient Electrical
Appliances and
Equipment used in a
patient care facility or
that contact patients in
normal use. Per section
10.3.5.1.
Less than 500 microamps
of leakage current at 264
Vac with the ground wire
disconnected, as required
for Non-patient Electrical
Appliances and Equipment
used in a patient care
facility or that contact
patients in normal use. Per
section 10.3.5.1.
Less than 100 microamps
of leakage current at 264
Vac with the ground wire
intact with normal polarity,
as required for Non-patient
Electrical Appliances and
Equipment used in a patient
care facility or that contact
patients in normal use. Per
section 10.3.5.1.
Power Supply Fan
N/A
50mm variable speed
70mm variable speed
N/A
Power cord length
6.0 ft. (1.83 m)
6.0 ft. (1.83 m)
6.0 ft. (1.83 m)
6.0 ft. (1.83 m)
Dimensions
113.5mm x 55mm x
30mm
200mm x 85mm x 53mm
165mm x 95mm x
73mm
90W : 132mm x 57mm x
30mm
120W : 148mm x 75.5mm x
25.4mm