Cord Matrix
Cord MatrixCord Matrix
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications
for UPS and PDU units:
ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf
.
System Fans
System FansSystem Fans
System Fans
Fully redundant hot plug fans ship standard (N+1).
Rack Airflow
Rack AirflowRack Airflow
Rack Airflow
Requirements
RequirementsRequirements
Requirements
Rack 10000 series Cabinets
Rack 10000 series CabinetsRack 10000 series Cabinets
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum
cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
CAUTION:CAUTION:
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be
a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION: CAUTION:
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE:
NOTE: NOTE:
NOTE:
For additional information, refer to the Setup and Installation Guide or the Documentation CD
provided with the server, or to the server documentation located in the Support section at the following
URL:
http://h18000.www1.hp.com/products/servers/proliantdl380/index.html
.
Rack Kit
Rack KitRack Kit
Rack Kit
The HP ProLiant DL380 G5 quick deploy rail system provides tool-free support for racks with square or
round mounting holes (including Compaq/HP 7000
*
, 9000, 10000 and HP series), with an adjustment
range of 24" - 36". The ambidextrous cable management arm can be mounted on either the left or right
side for improved cable management.
*High Airflow Inserts (High Air Flow Rack Door Insert for the 7142 Rack (single) - PN: 327281-B21; or
High Air Flow Rack Door Insert for the 7142 Rack (6-pack) - PN: 327281-B22) are required to support
the HP ProLiant DL380 G5 in 7000 series racks. The DL380 G5 Cable Management Arm is not
supported on 7000 series racks.
NOTE:
NOTE:NOTE:
NOTE:
Cable management arm must be removed to access hot-plug power supplies when the cable
management arm is mounted on the right.
Telco Rack Support
Telco Rack SupportTelco Rack Support
Telco Rack Support
DL380 G5 Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit
from Rack Solutions (
http://www.racksolutions.com/hp/
)
QuickSpecs
HP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage ServerHP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage Server
Standard Features
DA - 12559 EMEA — Version 20 — November 17, 2008
Page 12