Datasheet

System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
Full height server blade; 7.15 x 2.03 x 20.06 in (36.63 x 5.16 x 50.95 cm)
Weight
WeightWeight
Weight
(approximate)
Maximum
(all hard drives and
processors installed)
21.02 lb (9.53 kg)
Minimum
(one hard drive and
processor installed)
18.74 lb (8.50 kg)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
For power specifications including input requirements, BTU rating, and
power supply output, please see the HP BladeSystem c-Class Enclosures
QuickSpecs located at:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_div/
12810_div.html
To review typical system power ratings use the HP BladeSystem Power Sizer
available at:
http://www.hp.com/go/bladesystem/powercalculator
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
50° to 95°F (10° to 35°C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m ) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 86°F (30°C).
Non-Operating
-22° to 140°F (30° to 60°C), maximum rate of
change is 36°F/hr (20°C/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
Non-Operating
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
AltitudeAltitude
Altitude
Operating
10,000 ft (3050 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Acoustic NoiseAcoustic Noise
Acoustic Noise
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_div/
QuickSpecs
HP ProLiant BL480c Server Blade
HP ProLiant BL480c Server BladeHP ProLiant BL480c Server Blade
HP ProLiant BL480c Server Blade
Technical Specifications
DA - 12513 Worldwide — Version 38 — July 17, 2009
Page 23