User's Manual

Risks
Single path failure will result in loss of connection with the storage system.
Single path failure may cause the server to reboot.
Controller shutdown puts controller in a failed state that results in loss of data accessibility
and loss of host data that has not been written to storage.
NOTE: For additional risks, see “Windows Servers” (page 93).
Limitations
HP P6000 Continuous Access is not supported with single path configurations.
Single path HBA server is not part of a cluster.
Booting from the SAN is not supported on single path HBA servers.
Figure 31 Windows Server 2008 (64-bit) or Windows Server 2003 (64-bit) configuration
6. SAN switch 11. Network interconnection
7. Multiple single HBA paths2. Management server
8. SAN switch 23. Host 1
9. Controller A4. Host 2
10. Controller B5. Host 3
Oracle Solaris configuration
Requirements
Switch zoning or controller level SSP must be used to ensure each single path HBA has an
exclusive path to its LUNs.
Single path HBA server can be in the same fabric as servers with multiple HBAs.
82 Single path implementation