Datasheet

External Storage
External StorageExternal Storage
External Storage
Quantity
QuantityQuantity
Quantity
Supported
SupportedSupported
Supported
Position
PositionPosition
Position
Supported
SupportedSupported
Supported
Host Controller or Adapter
Host Controller or AdapterHost Controller or Adapter
Host Controller or Adapter
Modular Smart Array 50
Enclosure
2 per connector
(supports 1+1
cascading)
External
HP Smart Array P600/256 BBWC Controller
NOTE:
NOTE: NOTE:
NOTE:
Optional mixed PCI-X/E cage required.
Modular Smart Array 500
G2
1 per SCSI
External
Please see the Modular Smart Array 500 or 500 G2 QuickSpecs
for the latest list of supported HBAs:
http://www.hp.com/go/msa500
.
Maximum Storage Capacity
Maximum Storage Capacity Maximum Storage Capacity
Maximum Storage Capacity
- (SAS with MSA50)
Internal
1.168TB (8 x 146 GB SAS SFF)
External
2.920TB (20 x 146 GB SAS SFF)
Total
4.088TB
Tape and Disk-Based Backup
Tape and Disk-Based BackupTape and Disk-Based Backup
Tape and Disk-Based Backup
NOTE:
NOTE:NOTE:
NOTE:
For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/division/10233.html
(Worldwide)
NOTE:
NOTE: NOTE:
NOTE:
For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed below,
please see the following:
http://h18000.www1.hp.com/products/quickspecs/division/10809.html
(Worldwide)
NOTE:
NOTE:NOTE:
NOTE:
For complete listing of tape drive offerings see:
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
NOTE:
NOTE:NOTE:
NOTE:
SAS Tape Drives: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied with tape
drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs into SAS drive
connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would
mean drive bay 8 is deactivated.
Position
PositionPosition
Position
Supported
SupportedSupported
Supported
Controller
ControllerController
Controller
Controller Part
Controller PartController Part
Controller Part
Number
NumberNumber
Number
HP StorageWorks SCSI
HP StorageWorks SCSIHP StorageWorks SCSI
HP StorageWorks SCSI
Tape Drives, External
Tape Drives, ExternalTape Drives, External
Tape Drives, External
LTO-1 Ultrium 232
LTO-2 Ultrium 448
LTO-3 Ultrium 960
LTO-3 Ultrium 920
LTO-4 Ultrium 1760
LTO-4 Ultrium 1840
DAT 40
DAT 72
DAT 160
1U Rack-Mount Kit
3U Rack-Mount Kit
External
HP SC11Xe Host Bus Adapter
412911-B21
QuickSpecs
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
Storage
DA - 12565 Worldwide — Version 41 — July 23, 2008
Page 39