Specifications
Connecting lkrminals to Domain Compatible
Mode Systems
Youcan troubleshoot a Domain Compatible mode system that has displayprob-
lems by connecting a terminal to the systemS10 line. This section explainshow
to connect the standard field terminal or another node to the system’sS10 line.
Using a Field Terminal
Thedata terminal currently available for field use is a speciall modified IXO
model TC301.This device ISbattery powered with a l-line, 1
&haracter U2D
dis lay.The terminal communicates at 300baud only, and isconfigured as a
Zf
D E device.It
lu~ into the system, and its attached cable needs no adapters.
Perform the fol owingsteps to activate the field terminal:
1. Press the ON/OFF key.The terminal displaysthe followingmessage
HI, IXO ACCESSCENTER?
2 Press the NO key. The terminal displaysthe followingmessage
MANUAL, FULL
3. Press the PHONE key. The terminal displaysthe followingmessage:
LOGGING ON
The
terminal then displaysthe online mode indicator.
4. You are now ready to connect the field terminal to the systemand ac-
cess the MD.
Using a Workstation as a Terminal
If you need to use another workstation to emulate a terminal, type the following
next to the “$” shell prompt:
$ emt <RETURN>
When you receive the “emt >” prompt, enter the followingthree command
Iinw
emt > line 1 <RETURN>
emt > raw
emt > <Fl>
The workstation replies with the followingmessage:
enk >
EMT remote node . . . . F1 to exit
3-38 Configuration