Specifications
Table 5-7 listsand explainsthe messagesdis Iayed for Boot ROM failures.It
Y
also indicates proeedur~ to resolve the prob ems.
T&le 5-7. BootROM Di.rplqed FailureMessages
DisplayedMessage
Meaning and What to Do
CONTINUE
AT OWNRISK
A self-test wasnot completed. You may
(ENTERTo Cent inue) continue but errom may occur. Press
ENTER to restart power-up sequence.
CONTINUEAT OWNRISK
A self-test wasnot completed. You may
(RETURN To Cent inue) continue but errors may occur. Press
RETURN to restart power-up sequenee.
DATA PARITY ERRORAT
Parity error at (address). Replaee memory
(address)
module that has the indicated address.
F Disc Error
Error in disk drive. Troubleshoot disk
drive,
UEKORY FAILED AT (address)
Memory failed at (address). Refer to
Table 4-5 and Table 4-6.
Replace memory module.
MEMORY00NE AT (address) Memory not found at indiested address.
Replaee memory module that has the
indicated address
NOT ENOUGHMEMORY Not enough memory to load operating
operating system. Add more memory.
PARITY BIT ERROR AT Parity error at (address). Replace memory
(address)
module that has the indicated address.
RAMFAILED ABOVEFFFFCOOOI%iiurein top 16KB of memory.
Replaee memory in slot OA.
RAMGONE ABOVE FFFFCOOO
CPU could not find top 16ICEof
memory. Replace memory in slot OA.
SYS~E~MOU1.~l.OAllTOO An addressingerror would make the
HIGH
operating system try to load at too high
an address. Probable cause
● Bad media.
. Data tmnsfer error.
. Bad processor, interfam, or mass
storage deviee.
Try again. If error repeats, troubleshoot
above items.
(Continued)
Diagnostics
5-11