Figure 46 Inst alling a p ower supply
V erifying proper operation
After replacing the power supply, check the following to verify that the component is operating properly:
• Check the power supply status indicator. It should be green.
• Navigate back to the component and check the status. It should be
.
• Turn off the locate function by clicking Locate > Locate Off
Returning the failed component
Please follow the return instructions provided with the new component.
Replacing a disk drive
This section describes the procedure for replacing a Fibre Channel disk drive.
Before yo
ubegin
Observe t
he following precautions when replacing the disk drive.
CAUTION:
Make sure you have a replacement part available before removing the failed component. Removing a
component impacts cooling within the enclosure.
Do not remove more than one disk drive at a time from the enclosure. Doing so will impact cooling of the
enclosure and may cause data loss.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection. Refer to the
documentation that shipped with your system for additional information.
Have a copy of the product User Guide available for reference. You can download a copy of the User
Guide fr
om the product support page on the HP web s ite.
Verifying component failure
Before beg inning the replacement procedure, use the following methods to verify the component failure.
CAUTION:
IfCommandViewEVAdoesnotpresentastatusconsistentwiththatofthediskdrivestatusindicators,or
if Command View or the System Event Analyzer indicates multiple hardware failures, contact H P support
for assistanc e. The HP support web site is loc ated at h
ttp://www.hp.com/support
98
Customer replaceable units