Owner's manual

Figure 40 Installing a battery
V erifying proper operation
After replacing the batter y, check the following to verify that the component is operating properly:
NOTE:
It may take up to 10 minutes for the component to display good status.
Check the bat tery status indicators. See Table 28
•Duringtherst minute, both status indicators may be on or ashing.
The status indicator (1) shou ld then begin ashing, indicating the battery is charging. It
may take several hours for a new battery to fully charge. The fault indicator (2) should be
off during charging.
After checking the status indicator, install the front panel on the enclosure by pressing it rmly
into place.
From Command View EVA
Navigate back to the component and check the status. It should be
.
TurnoffthelocatefunctionbyclickingLocate > Locate Off
Replacing a controller blower
This section describes the procedure for replacing the blower used in Enterprise Virtual Array (EVA)
products.
Before you begin
Observe the following precautions when replacing a blower.
CAUTION:
Removing a blower signicantly changes the air ow within the enclosure. Both blowers must be installed
for the enclosure to cool properly. If a blowers fails, leave it in place in the enclosure until a new blower
is available to install.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection. Refer to the
documentation that shipped with your system for additional information.
Have a copy of the product User G uide available for reference. You can download a copy of the User
Guide from the product support page on the HP web site.
Verifying component failure
Before replacing a blower, use the following methods to verify the component failure:
4000/6000/8000 Enterprise Virtual Array user guide
93