Owner's manual

NOTE:
When viewing the
softwar e or rmware version information, pressing
displays the Versions Menu tree.
To display System Information
1. The default display alternates between the Storage System Na m e display and the World Wide
Name display.
Press any p ush button to select the Storage System Menu Tree display.
2. Press
until the desired Versions Menu o ption appears, and then press or to move to
sub–menu items per Table 24.
Shutting down the system
CAUTION:
To power off the system for more than 96 hours, use HP Command Vie w EVA.
You can use the Shutdown System function to implement the shutdown methods listed below. These
shutdown methods are explained in Table 25.
Shutting dow
n the controller (see Shut ting the controller down).
Restarting the system (see Restarting the System).
Uninitializing the system (see Uninitializing the System).
To ensure that you do not m istakenly activate a shutdown procedure, the default state is always NO,
indicating
do not implement th is procedure. As a safeguard, implementing any shutdown method
requires you to complete at least two actions.
Table 25 Shutdown methods
LCD prompt Description
Restart System?
Implementing this procedure establishes communications between the storage
systemandHPCommandViewEVA.Thisprocedureisusedtorestore
the controller to an operational state where it can c ommunicate with HP
Command View EVA.
P ower off system? Implementing this procedure initiates the sequential removal of controller
power. Thisensuresnodataislost. Thereasonsforimplementingthis
procedure include replacing a drive enclosure.
Uninitialize?
Implementing this procedure will cause the loss of all data. For a detailed
discus sion of this procedure, see Uninitializing the System.
Shutting the controller down
Use the following procedure to access the Shutdown System display and execute a shutdown procedure.
NOTE:
HP Command View EVA is the pr eferred method for shutting down the controller. Shut down the
controller from the OCP only if HP Command View EVA cannot communicate with the controller.
Shutting down the controller from the OCP removes power from the controller on which the procedure is
performed only. To restore power, toggle the controller’s power switch.
74
Enterprise Virtual Array hardware components