2. Insertthedriveintotheenclosureasfarasitwillgo(1,Figure 9).
3. Close the release lever until it engag es the ejector button, a nd the disk d rive seats in the backplane
(2 , Figure 9).
4. Press in rmly on the disk drive to ensure it is seated properly.
0116a
2
1
Figure 9 Installing t he disk drive
Checking status indicators
After replacing the disk d rive, check the following to verify that the disk drive is operating normally:
NOTE:
It may tak
e up to 10 minutes for the component to d isplay good status.
Check the disk drive status indicators. See Figure 10.
•Activityindicator(1)shouldbeonorashing
Online indicator (2) should be on or ashing
Fault indicator (3) should be off
Check the following using Command View EVA.
Navigate to the disk drive and check the operational state. It should be
.
Ensure the disk drive is using the correct rmware. Check the Firmware Version against
the supported disk rmware in the HP StorageWorks Enterprise Virtual Array release notes.
Themostcurrenteditionofthereleasenotescanbedownloadedfromthefollowingweb
site:h
ttp://www.hp.com/go /eva8000. If the disk drive is using an unsupported version of
rmware, contact HP support for assistance. Do not ad d the disk drive to a disk group if
it using an unsupported rmware version.
42