Owner's manual

Example 2. Restoring co nguration d a ta using SSSU on a Windows Hos t
If it is necessary to restore the storage system conguration, it can be done using the
1. Click Run on the Window Start m enu.
2. Enter cmd in the Open eld to open the DOS Command Window.
3. Change to the directory (CD) in which you have installed SSSU. For example, C:> cd \SSSUDir
4. Enter SSSU to run the application.
5. Enter FILE <pathname\filename>,wherepathname identies the location where the
conguration les are b e saved and lename is the name of the rst conguration le. For example,
FILE c:\EVAConfig\LargeEVA_Step1A.txt
6. Repeat the preceding step for e ach conguration le.
Adding disk drives to the storage system
As your storage requirements grow, you may be adding disk drives to your storage system. Adding new
disk drives is the easiest way to incre ase the storage capacity of the storage system. Disk drives can be
added onli
ne without impacting storage system operation.
Guidelines for a dding disk drives
When adding new disk drives to the storage system, you should ensure that the disk drives are installed
in the correct positions to maintain availability. The disk drives should be distributed across the disk
enclosures to protect against the failure of a single disk enclosure.
Use the following guidelines when adding disk drives to your storage system:
Install high performance and FATA disk drives in separate g roups. These different drive types must
be in separate disk groups. You m ay also want to consider separating different drive capacities
and spindle speeds into different groups.
The disk drives should be distributed evenly across the disk enclosures. The number of d isks of
a given type in e ach enclosure should not differ by more than one. For example, no enclosure
should have t wo disks until all the other enclosures have at least one.
Disk drives should be installed in vertical columns within the disk enclosures. Add drives vertically
in multiples of eight, completely lling columns if possible. Disk groups are more robust if lled
with the same number of disk drives in each enclosure. See Figure 7 for an example.
NOTE:
When adding multiple disk drives, add a disk and wait for its activity indicator (1) to stop ashing
(up to 90 seconds) before installing the next disk (see Figure 6). This procedure must be followed to
avoid unexpected EVA system behavior.
4000/6000/8000 Enterprise Virtual Array user guide
39