Owner's manual

Browser
Host X
FCA
Management
Server
Command
View EVA
CXO8055
D
Controller
A
FCA FCA FCA
Host Z
Browser
Non-Host
FP1 FP2
Loop
Pair 1
Loop
Pair 1
Controller
B
FP1 FP2
Network Interconnection
Drive Enclosures
F
P = Fibre (Host) Port
F
CA = Fibre Channel Adapter
Cache
Mirror Ports
B
A
B
A
Fabric 1
Fabric 2
Figure 4 EVA4000/6000 conguration
Dir ect connect
NOTE:
Direct connect is currently supported on Microsoft Windows only. Refer to the
HP StorageWorks
Enterprise Virtual Array 4000/6000/8000 release notes
for more information on direct connect support.
Direct connect provides a lower cost solution for smaller congurations. When using direct connect, the
storage system controllers are connected directly to the h ost(s), not to SAN Fibre Channel switches. Make
sure the following requirements are met when conguring your environment for direct connect:
A Windows host running HP Command View EVA must be connected to one port on each EVA
controller. The management host must use dual HBAs for redundancy.
To provide redundancy, it is recommended that dual HBAs be used for each additional host
connected to the storage system. Using this conguration, up to four hosts (including the
management host) can be connected to an EVA8000, and up to two hosts c an be connected to
an EVA6000 or EVA4000.
The Host Port Conguration must be set to Direct Connect using the OCP.
HP Continuous Access cannot b e used with direct connect con gurations.
28
Enterprise Virtual Array startup