0.1.en.04 CRITICAL condition—Loop a drive link rate incorrect
The drive is capable of operating at the loop link rate b ut is running at a different rate. For example, the
drive is operat
ing at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating at
the Fibre Chann
el link rate established by the I/O module can this drive transfer da ta.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Remove and rep
lacethedriveintheenclosure.
3. Observe the drive status indicators to ensure the drive is operational.
4. Observe the EMU to ensure the error is corrected.
5. If removing a
nd replacing the drive did not correct the problem, replace the drive.
6. Observe the drive status indicators to ensure the drive is operational.
7. Observe the EMU to ensure the error is corrected.
8. If unable to
correct the problem, contact your authorized service representative.
0.1.en.05 CRITICAL condition—Loop b drive link rate incorrect
The drive is capable of operating at the loop link rate b ut is running at a different rate. For example, the
drive is op erating at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating at
the Fibre Channel link rate established by the I/O mod ule can this drive transfer da ta.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Removeandreplacethedriveintheenclosure.
3. Observe the drive status indicators to ensure the drive is operational.
4. Observe the EMU to ensure the error is corrected.
5. If removing and replacing the drive did not correct the problem, replace the drive.
6. Observe the drive status indicators to ensure the drive is operational.
7. Observe the EMU to ensure the error is corrected.
8. If unable to correct the problem, contact your authorized service representative.
Power supply conditions
The format of a power supply condition report is 0.2.en.ec,where:
0.2. is the power supply element type number
en. is
the two-character power supply element numb er
ec is the error code
Figure 56 shows the loca tion of power supply 1 and power supply 2.