Maintenance and Service Guide

Multi-pin horizontal insert connector (LVDS cable to display panel)
Insert procedure:
1. Slide connector evenly into receptacle on same horizontal plane as PCB connector.
2. Pull lock bar to insert and push both side connector horizontally to rmly lock.
3. Tape down lock bar over the panel to hold in position.
Reverse the procedure above to remove the connector:
1. Remove tape.
2. Pull up bar (pull tape) and release the lock with the PCB connector.
3. Pull to the direction in parallel with PCB to withdraw the connector.
Multi-pin vertical insert connector (LVDS cable to system board)
Remove the connector gasket prior to removing the connector.
Use at tool under the connector to remove evenly. Do not pull on the cable to remove.
Press evenly when reseating/reconnecting/installing the connector.
For more information about cable management, see Cable management on page 159.
Additional information 161