5 Installing HP 3PAR SRA
You cannot upgrade to HP 3PAR SRA 5.5.2 from an earlier version. Therefore, you must remove
the earlier version before installing HP 3PAR SRA 5.5.2.
If HP 3PAR SRA 5.5.1 is installed, then run the following command before you remove SRA 5.5.1:
TPDSrm.exe removecert—To delete the accepted HP 3PAR StoreServ certificate
from the cache memory.
Removing HP 3PAR SRA
To remove HP 3PAR SRA, do the following:
1. Log on as system administrator.
2. Click Start→Control Panel→Programs and Features.
3. Select HP 3PAR SRA Software Version <x.x>.
4. Click Remove.
The Program Maintenance dialog box appears.
5. Select Remove and click Next.
Installing HP 3PAR SRA 5.5.2
To install HP 3PAR SRA 5.5.2, do the following:
1. Double-click the installation executable to launch the installation wizard. Click Next to continue.
NOTE: HP 3PAR SRA and SRM must be installed on the same host.
2. Click I Agree to acknowledge the User License Agreement, and click Next to continue.
3. Click Next to start installation at the default path.
4. After the installation is complete, restart the VMware vCenter Site Recovery Manager service
to ensure that HP 3PAR SRA is recognized by SRM.
NOTE: This package can only be installed under the existing VMware® vCenter Site Recovery
Manager™ installed path. No other installation location is provided as an option.
Verifying installation
To verify the installation of HP 3PAR SRA 5.5.2:
1. Click Start →Control Panel→Programs and Features.
2. Verify that HP 3PAR SRA Software Version 5.5.2 appears in the Currently installed programs
column.
Removing HP 3PAR SRA 9