User's Guide
Scope: This may be experienced when an adddestination –type 3PAR command is issued
with the –secure=true and –port flags included.
Solution: If the above error occurs, the HP-3PAR-MC-TrustStore keystore file must be created
or modified in the <userhome dir>\InformMC\Security folder and copied into the folder
as shown in the error message, such as C:\InformMC\Security in the above example. To
copy the keystore file to the correct folder, follow these steps:
NOTE: If you have already added one HP 3PAR StoreServ Storage system, the
HP-3PAR-MC-TrustStore file will be updated for that storage system. The same
HP-3PAR-MC-TrustStore file should be updated for each HP 3PAR StoreServ Storage system
that you want to add as a destination storage system.
1. Close the HP 3PAR Online Import Utility for EMC Storage.
2. Locate the TrustStore file as displayed in the error message. Copy the
HP-3PAR-MC-TrustStore file, if available, to the logged in user’s home directory at:
\InFormMC\security
You can use the echo command, %HOMEDRIVE%%HOMEPATH%, to find the current user’s home
directory.
3. Using the command prompt, browse to the install location:
C:\Program Files (x86)\Hewlett-Packard\hp3paremcoiu\bin
...and run the following command:
TPDCertVerifier.bat
4. Enter the IP address of the HP 3PAR StoreServ and see its certificate details.
If you accept the certificate, the TrustStore file will be updated in the user’s home directory.
5. Replace the existing HP-3PAR-MC-TrustStore file as displayed in the error message with
the newly updated HP-3PAR-MC-TrustStore file in the user’s home directory.
6. Restart the HP 3PAR Online Import Utility for EMC Storage, and execute the adddestination
command again to add the HP 3PAR StoreServ Storage System.
createmigration command may not be successful during AdmitVV phase due to an
improper Failover mode setting on the EMC storage controller
Problem: A createmigration command failure may occur during the admitvv phase due to
an improper EMC Storage controller failover mode setting.
Example 67 Error message—example 1
>createmigration -sourceuid 50060160BEA00351 -srcvolmap [{"EMC_1"}] -destcpg FC_r5 -destprov full -migtype
offline
>SUCCESS: Migration job submitted successfully. Please check status/details using showmigration command.
Migration id: 1406202011980
>showmigration
MIGRATION_ID TYPE SOURCE_NAME DESTINATION_NAME START_TIME
END_TIME STATUS(PROGRESS)(MESSAGE)
1406202011980 MDM CLARiiON+APM00140110205 TAY-7200-04 Thu Jul 24 07:40:11 EDT
2014
-NA- preparationfailed(-NA-)(:OIUERRDST0008:Admit has failed. Volume
60060160FF1137005D6BECAEBA06E411 was not admitted;0 VVs admitted.;)
Typical HP 3PAR Eventlog entries will show admitvv, Test/Device not Unit Ready errors:
Troubleshooting Issues 99