User's Guide
An “unexpected error” message when destprov/destcpg are not specified for all
LUNs
Problem: ERROR: OIUERRAPP0000 on createmigration using srcvolmap. This is an example
of the error:
>createmigration -sourceuid 50060160C6E0167A -srcvolmap [{"temp_1", thin, "FC_r6"}]
-migtype MDM
>ERROR: OIUERRAPP0000 An unexpected error occured. OIURSLAPP0000 Contact HP support.
You may try restarting the application service.
Solution: This error can occur when the source array storage group contains multiple volumes but
only one of the volumes is specified in the srcvolmap. In this case, the default destprov and destcpg
parameters must also be included in the createmigration command. Without this, the migration
behavior for the volumes not specified in the srcvolmap is not known. The createmigration
command should look similar to this:
createmigration -sourceuid 50060160C6E0167A -srcvolmap [{"temp_1"}] -migtype MDM
-destcpg "FC_r6" -destprov thin
>SUCCESS: Migration job submitted successfully. Please check status/details using
showmigration command.
Migration id: 1400681640423
Error message when source array LUN has persistent reservation
Problem: OIUERRMS10006:Failed to start Data transfer. Failed to find SCSI PGR keys on
destination... message after startmigration issued.
Solution: This error can occur when one or more of the LUNs in the storage group being migrated
has a persistent reservation. Once this error occurs, no further attempt to migrate any of the LUNs
in the storage group.
An adddestination Command May Fail When HP 3PAR Online Import Utility for
EMC Storage Attempts to Connect an HP 3PAR Storage System when using Secure
Connections
Problem: An adddestination –type 3PAR command may fail when the Online Import for
EMC Storage Utility is trying to connect using secure connection mode and cannot validate a
certificate.
Example 66 Example error
>adddestination -type 3PAR -mgmtip xx.x.xx.xx -user 3paradm -password 3pardata -secure true
-port 5783
>ERROR: OIUERRDST0010 Unable to validate certificate. C:\\InFormMC\security\HP-3PAR-MC-TrustStore
If, during HP 3PAR OS installation, ‘yes’ is chosen to disable non-encrypted ports (closing ports
5781 and 5782), the installation will leave encrypted port 5783 enabled.
If disabling non-encrypted ports is true, then the -secure and -port flag must be included in
the adddestination –type 3PAR command.
NOTE: -secure and -port are optional parameters. They need to be included only when you
are using the secure connection mode.
If the error message above occurs, the HP-3PAR-MC-TrustStore keystore file must be created in the
<userhome dir>\InformMC\Security directory and copied into the directory as shown in
the error message (C:\InformMC\Security in the example above).
98 Troubleshooting