User's Guide
Prerequisites
• EMC SMI-S Provider is installed and operational.
• The source EMC Storage system must be registered in the EMC SMI-S Provider application.
• HP 3PAR Online Import Utility is installed and operational with network access to both the
EMC SMI-S Provider server managing the source storage system and the destination HP 3PAR
StoreServ Storage system.
• Source EMC Storage system and destination HP 3PAR StoreServ Storage system are zoned
to each other.
Required Information
Source Storage System:
• IP address of the EMC SMI-S Provider server that is managing the source EMC Storage system
from which the volumes are being migrated.
◦ If the SMI-S server is managing more than one source EMC Storage system and you only
want to identify one of them you need to know the WWN of the source storage system.
• User name and password for the EMC SMI-S Provider server.
• Port to access EMC SMI-S Provider.
Secure port default 5989.◦
◦ Non-secure port default 5988.
Destination HP 3PAR StoreServ Storage system:
• IP address of the destination HP 3PAR StoreServ Storage system.
• User name and password for the HP 3PAR management application with Super user permission.
Identifying the Source Storage System
To identify the source storage system, follow these steps:
1. From the HP 3PAR Online Import Utility, execute the addsource command.
NOTE: Use your local host user name and password credentials to log into the HP 3PAR
Online Import Utility.
Example 48 addsource command
>addsource -type VNX -mgmtip 10.10.10.10 -user admin -password adminpw -uid
xxxxxxxxxxxxxxxx
>SUCCESS: Added source storage system
2. Execute the showsource command to verify the source storage system information.
Example 49 showsource command
>showsource –type VNX
NAME TYPE UNIQUE_ID FIRMWARE MANAGEMENT_SERVER OPERATIONAL_STATE
CLARiiON+APM00125345014 VNX 50067890BEE0177F 05.32.000.5.201 10.10.10.10 Good
Identifying the Destination Storage System
To identify the destination procedure, follow these steps:
Identifying the Source and Destination Storage Systems 67