User's Guide

Example 68 Error message—example 2
Time : 2014-07-24 07:41:32 EDT
Severity : Minor
Type : CLI command error
Message : {3paradm super all {{0 8}} -1 15.234.144.106 27814} {Command: admitvv EMC_1:XXXXXXXXXXXXXXXXXX Error:
Volume XXXXXXXXXXXXXXXXXXXX was not admitted--0 VVs admitted.} {}
Time : 2014-07-24 07:41:33 EDT
Severity : Informational
Type : Disk event
Message : target WWN XXXXXXXXXXXXXXX on 0:1:2: cmdstat:0x1e (TE_UNITATT -- Unit attention error),
scsistat:0x02 (Check condition), snskey:0x06 (Unit attention), asc/ascq:0x29/0x0 (Power on, reset, or bus device
reset occurred), info:0x0, cmd_spec:0x0, sns_spec:0x0, host:0x4, abort:0, CDB:000000000000 (Test unit ready),
blk:0x0, blkcnt 0x0, fru_cd:0x0, LUN:2, LUN_WWN:XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX after 0.000s, toterr:44219,
deverr:1
Workaround: In order for the createmigration command to complete successfully, the EMC
Storage controller failover mode must be set to 4 (Active/Active). Failover Mode 4 is ALUA.
This allows the HP 3PAR peer port initiators to access LUNs through the noncontrolling EMC SP
controller.
The EMC Storage controller failover mode may be displayed and edited by using EMC Naviseccli
CLI commands.
To display the current default EMC Storage controller failover mode, execute the following EMC
Naviseccli CLI command:
C:\> naviseccli -address <SP Controller IP address> failovermode
Current failovermode setting is: 1
Any value other than 4 (Active/Active) indicates either a configuration issue or a
hardware/software issue with the EMC Storage controller. The issue must be corrected before
proceeding with data migration.
To change the EMC Storage controller failover mode, follow these steps:
1. Configure the EMC storage controller failover mode to 4 (Active/Active). This may
require resolving any hardware/software or configuration issues which may have led to the
condition.
Example 69 Editing the default EMC Storage controller failover mode
C:\> naviseccli -address <SP Controller IP address> failovermode 4
WARNING: Previous Failovermode setting will be lost!
DO YOU WISH TO CONTINUE (y/n)? y
2. Unzone the HP 3PAR peer ports from the EMC array.
3. Deregister the HP 3PAR Peer Port initiators from the EMC array.
4. Rezone the HP 3PAR peer ports with the EMC array.
IMPORTANT: Each HP 3PAR Peer Port initiator must have its failover mode set to 4 before
you execute the createmigration command.
Error when Importing LUN of Size Smaller than 256 MB
Problem: After a createmigration command is executed with a LUN of size less than 256 MB,
the following message occurs following a showmigration command: "OIUERRDST0008: Admit
has failed ..."
Solution: Increase the size of the source LUN on the EMC Storage array to a minimum of 256 MB,
and then retry the createmigration command.