Specifications
3-32
Cisco NAC Appliance - Clean Access Manager Configuration Guide
OL-28003-01
Chapter 3 Switch Management: Configuring Out-of-Band Deployment
Configure OOB Switch Management on the CAM
• Type the Community String for SNMP V1 or SNMP V2C configured for the switch.
Step 6 If SNMP V3 is used for SNMP Read Settings on the switch, configure the following settings to match
those on the switch:
• Choose a Security Method from the dropdown menu: NoAuthNoPriv, AuthNoPriv(MD5),
AuthNoPriv(SHA), AuthPriv(MD5+DES), or AuthPriv(SHA+DES).
• Type the User Name.
• Type the User Auth.
• Type the User Priv.
Step 7 Configure SNMP Write Settings to match those on the switch.
• Choose the SNMP Version: SNMP V1, SNMP V2C, or SNMP V3.
• Type the Community String for SNMP V1 or SNMP V2C configured for the switch.
Step 8 If SNMP V3 is used for SNMP write settings on the switch, configure the following settings to match
those on the switch:
• Choose a Security Method from the dropdown menu: NoAuthNoPriv, AuthNoPriv(MD5),
AuthNoPriv(SHA), AuthPriv(MD5+DES-CBC), or AuthPriv(SHA+DES-CBC).
• Type the User Name.
• Type the User Auth.
• Type the User Priv.
Step 9 Click Add to add the Switch profile to OOB Management > Profiles > Device > List (Figure 3-28).
Figure 3-16 illustrates a switch profile defining Cisco Catalyst 2950 switches with the same SNMP
settings: SNMP V2c with read community string “c2950_read” and write community string
“c2950_write.”