User Manual

EMU Generated Condition Reports
181Enterprise Virtual Array 3000 User Guide
Transceiver Conditions
The format of a transceiver condition report is 0.F.en.ec, where:
0.F. is the transceiver element type number
en. is the two-character transceiver element number (see Figure 68)
ec is the error code
0.F.en.01 CRITICAL ConditionTransceiver Incompatibility
The transceiver on this link are not the same type or they are incompatible with the
I/O module. This error prevents the controller from establishing a link with the
enclosure drives and eliminates the enclosure dual-loop capability. This error
remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
0.F.en.02 CRITICAL ConditionTransceiver Data Signal Lost
This symptom can occur when a controller has been powered Off or a cable has
been removed from the transceiver. The transceiver can no longer detect a data
signal. This error prevents the controller from transferring data on a loop and
eliminates the enclosure dual-loop capability. This error remains active until the
problem is fixed.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
1 Transceiver 01
2 Transceiver 02
3 Transceiver 03
4 Transceiver 04
Figure 68: Transceiver element numbering
CXO7954A
3 1
4 2