Manual

1. Align the blower guide post (2, Figure 37) with the mounting hole next to the power supply
connector (1).
2. Slide the blower onto the power supply (4) u ntil the mounting tabs (3) snap into place.
Figure 37 Installing a blower
Removing a power supply
CAUTION:
When a power supply is removed, the enclosure could shut down within seven minutes due to overheating
unless the p
ower supply is replaced.
1. Disengage the power cord lock (1, Figure 38) and disconnect the power cord from the power supply.
CAUTION:
When remov ing the left power supply, ensure the cord lock on the right power supply is
engaged. This will avoid inadvertently disconnecting the right power supply. Also take care
to avoid disrupting the cables on the I/O module to left of the power supply.
2. Lift up on the wine-colored mounting latch (2), then g rasp the blower (3) and pull the power supply
out of the enclosure.
3. Remove the blower from the defective power supply and install it on the replacement power supply.
Enterprise Virtual Array 3000/5000 user guide